 |
| Trusted by Thousands of Surgeons Worldwide |
• With more than two-dozen tip configurations and sizes, Megadyne offers blade, needle, and ball electrodes to meet the needs of numerous electrosurgery procedures.
• The green E-Z Clean® modified tips are insulated everywhere but the distal 3-5 mm of the electrode shaft, minimizing the likelihood of damage to surrounding tissue.
• Surgeons can get the performance of Megadyne's E-Z Clean® nonstick tops for every procedure at costs comparable to stainless steel with our pencil and tip savings program.
|
| Modified Tip Electrodes Provide Highest Precision for Confined-Space Procedures |
• Only 4 mm of the distal tip is exposed thus minimizing the likelihood of alternate site thermal injuries.
• Features new modified PTFE insulation that resists splitting in temperatures beyond 700° F.
• Proprietary E-Z Clean® PTFE-coated tips save time by reducing eschar build-up.
• Reduce eschar build-up enables surgeons to use lower power settings.
|
| Protective Nose Cone Electrodes for High Moisture or Confined-Space Procedures |
• Protective nose cone reduces risk of inadvertent thermal burns caused by moisture-induced alternate current pathways..
• MInimizes chances of moisture wicking into the hand piece.
• Features new modified PTFE insulation that resists splitting in temperatures beyond 700° F.
• Proprietary E-Z Clean® PTFE-coated tips save time by reducing eschar build-up.
|
E-Z CLEAN LAP ELECTRODES »
MEGA SOFT RETURN ELECTRODES »
MEGA POWER GENERATOR » |
|
|
|
|
|
| E-Z Clean Blade Electrodes |
|
2.5 inch (6.35 cm), Standard Blade Electrode |
0012 |
Sterile, Single use, 12 |
|
2.75 inch (7 cm), X-Long Standard Blade Electrode |
0012A |
Sterile, Single use, 12 |
|
4 inch (10.16 cm), Extended Blade Electrode |
0014A |
Sterile, Single use, 12 |
|
6.5 inch (16.51 cm), Extended Blade Electrode |
0014 |
Sterile, Single use, 12 |
E-Z Clean MODIFIED Electrodes |
|
2.5 inch (6.35 cm), Standard Blade Electrode Modified |
0012M |
Sterile, Single use, 12 |
|
2.75 inch (7 cm), X-Long Standard Blade Electrode Modified |
0012AM |
Sterile, Single use, 12 |
|
4 inch (10.16 cm), Extended Blade Electrode Modified |
0014AM |
Sterile, Single use, 12 |
|
6.5 inch (16.51 cm), Extended Blade Electrode Modified |
0014M |
Sterile, Single use, 12 |
PROTECTIVE NOSE CONE E-Z Clean Electrodes |
|
2.5 inch (6.35 cm), Blade Electrode Modified with PTFE Insulation and Nose Cone |
0012MD |
Sterile, Single use, 24 |
|
2.75 inch (7 cm), Blade Electrode Modified with PTFE Insulation and Nose Cone |
0012AMD |
Sterile, Single use, 24 |
|
4 inch (10.2 cm), Blade Electrode Modified with PTFE Insulation and Nose Cone |
0014AMD |
Sterile, Single use, 24 |
|
6.5 inch (16.5 cm), Blade Electrode Modified with PTFE Insulation and Nose Cone |
0014MD |
Sterile, Single use, 24 |
|
2.75 inch (7 cm), Needle Electrode Modified with PTFE Insulation and Nose Cone |
0013MD |
Sterile, Single use, 24 |
| |
|
|
|
|